• Đồng hồ vạn năng số Fluke 101

  • Đăng ngày 02-08-2016 03:53:42 AM - 661 Lượt xem
  • Giá bán: Liên hệ

  • Đồng hồ vạn năng số Fluke 101.Designed for basic electrical tests, the Fluke 101 digital multimeter offers reliable measurements for residential/commercial electricians and heating and air conditioning technicians.


Số lượng

Fluke 101 Basic Digital Multimeter  

  • Basic dc accuracy 0.5%
  • CAT III 600 V safety rated
  • Diode and continuity test with buzzer
  • Small lightweight design for one-handed use
  • Rugged, durable design
  • Automatic shutdown
  • Battery is easy to replace

 

Fluke i400E AC Current Clamp

  • Compatible with most Fluke multimeters or mV ac measurement tools with these features:
    • 400 mV ac range
    • 19.05 mm banana jack inputs
    • Input accuracy of 2 % or greater to take full advantage of the accuracy of the product
    • Input impedance of >1 MΩ
  • 1 mV/A ac output guarantees easy current readings on you meter
  • CAT III 600 V safety rating
  • Specially designed to offer maximum utility in a very compact shape
  • Take accurate current readings

Fluke 101 Basic Digital Multimeter
 

Electrical Specifications
V AC (40-500Hz) Range 600.0 mV
6.000 V
60.00 V
600.0 V
Resolution 0.1 mV
0.001 V
0.01 V
0.1 V
Accuracy 3.0%±3 digit
1.0%±3 digit
V DC Range 6.000 V
60.00 V
600.0 V
Resolution 0.001 V
0.01 V
0.1 V
Accuracy 0.5%±3 digit
Resistance Ohms Range 400.0 ?
4.000 k?
40.00 k?
400.0 k?
4.000 M?
40.00 M?
Resolution 0.1 ?
0.001 k?
0.01 k?
0.1 k?
0.001 M?
0.01 M?
Accuracy 0.5 %±3 digit
0.5 %±2 digit
0.5 %±2 digit
0.5 %±2 digit
0.5 %±2 digit
1.5%±3 digit
Capacitance Range 50.00 nF
500.0 nF
5.000 µF
50.00 µF
100.0 µF
Resolution 0.01 nF
0.1 nF
0.001 µF
0.01 µF
0.1 µF
Frequency 
(10 Hz – 100 kHz)
Range 50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz
Resolution 0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz
Duty Cycle Range 0.1 % to 99.9 %
Resolution 0.1 %
General Specifications
CAT Rating CAT III 600 V
V AC Range 600.0 V
V DC Range 600.0 V
Ohms Range 40.00 M?
Auto Shutoff Y
Continuity Y
Capacitor 100.0 µF
Frequency 100.0 kHz
Hold No
Duty Cycle Yes
Size 130 mm x 65 mm x 27mm 
Weight 160 g
Battery Two AAA
Warranty 1 year
Environmental Specifications
Operating Temperature 0 °C to +40 °C
Storage Temperature -30 °C to +60 °C
Operating Humidity Non condensing (<10 °C)
<=90% RH (at 10 °C to 30 °C)
<=75% RH (at 30 °C to 40 °C)
(Without Condensation)
Operating Humidity, 40 M? 80% RH 10 °C to 30 °C, 70% RH 30 °C to 40 °C
Operating Altitude 2,000 meters
Storage Altitude 12,000 meters
IP Rating IP 40 per IEC 60529
Vibration Requirements MIL-PRF-28800F, Class 2
Drop Test Requirements -10°C and 1 meter to surface, per IEC-61010-1, and Fluke SOP 39.1 for portable Hand-held equipment
Shipping container drop per Fluke SOP 39.
EMI, RFI, EMC Must meet all applicable requirements in 
IEC/EN 61326-1
Absorption/Corrosion Per Fluke SOP 39.1
Temperature Coefficients Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 ºC

Fluke i400E AC Current Clamp

Electrical specifications
AC current range

1 A to 400 A

Output signal 1 mV/A ac
Accuracy 2.0 % ± 5 digits (45 Hz to 65 Hz)
2.5 % ± 5 digits (65 Hz to 400 Hz)
Typical bandwith 5 Hz to 20 kHz
Working voltage 600 V ac rms, in compliance with IEC 61010-1 and IEC 61010-2-030
Load impedance 1 A to 400 A
Maximum non-destructive current 600 A
Jaw inner diameter 30 mm
Maximum wire size 600 MCM
Standard plugs 19.04 mm dual banana plugs
Safety specifications
Category rating IEC 61010-1 and IEC 61010-2-030/IEC 61010-2-031 and
IEC 61010-2-032: 600 V CAT III
Pollution Degree 2
Electromagnetic environment IEC 61326-1: Portable
General Specifications
Output cable length 1 m
Operating temperature -10 °C to +50 °C
Storage temperature - 30 ºC to +60 ºC
Relative humidity =90 % at 10 °C to 530 °C;
=75 % at 30 °C to 540 °C;
=45 % at 40 °C to 50 °C
IP rating IEC 60529: IP30 when jaw closed
Temperature coefficients Add 0.1 x specified accuracy for each °C above 28°C or below 18 °C.
Operating altitude 2,000 meters
Storage altitude 12,000 meters
Vibration requirements MIL-PRF-28800F, Class 2
Drop test requirements -10 °C, 1m, 6 sides, oak wood
Jaw impact test requirements Follow EN/IEC 61010-2-032:2012
EMI, RFI, EMC IEC/EN 61326-1
Dimensions (hxwxd) 146 mm x 62 mm x 34 mm
Weight 150 g

 